Hole C0010A, J-CORES, Expedition 365

This URL provides the access to the most recent output from J-CORES database. The output is being overwritten as often as possible.

Hole C0010A, Expedition 365
Latitude33°12′35.8859″N
Longitude136°41′11.54″E
Water depth2523.7 m

This data set was output from J-CORES database by using its complete Bulk Export function Version 1.9.9 from 2017-08-07T00:45:17Z till 2017-08-07T00:45:31Z. The specification of the outputs is available to be referred. J-CORES Bulk Exports a file bulk.csv with various attachment files (e.g. image files). Files bulk-something.csv are generated by picking some kinds of data from bulk.csv. Files something.zip consist of bulk-something.csv and related attachment files. Files bulk-something.csv are in character encoding UTF-8 with line ending characters CRLF. J-CORES has a flexibility to store numerical/text values and attached files for user-defined parameters, which are output into User-Defined Parameter column group in bulk.csv. To know J-CORES software program, visit J-CORES' web site.

File Contents Length (bytes)
bulk-hole.csv Expedition, site and hole records 753
bulk-miscellaneous-material.csv Records of materials recovered from holes excepting cores 1282
sample.zip Records of ship and personal samples taken from core sections and miscellaneous materials 5649
bulk-other-liquid-chemistry.csv Chemistry for other kinds of liquid 18612
bulk-other-gas.csv Gas analyses for other kinds of samples 1612

The user-defined parameters are listed with their definitions as the followings.

osmo liquid chemistry
Measurements for liquid samples collected by using Osmotic sampler.
osmo liquid chemistry::refractive index nD: refractometer
Refractive index nD using a refractometer. dimensionless quantity
osmo liquid chemistry::salinity: refractometer [permil]
Salinity using a refractometer. permillage
osmo liquid chemistry::pmH: pH electrode, attached to titrator
pmH on free hydrogen ion concentration scale using a pH electrode attached to titrator. dimensionless quantity
osmo liquid chemistry::alkalinity: titrator [mM]
Alkalinity using a titrator. milli-molar
osmo liquid chemistry::chlorinity: titrator, potentiometric titration [mM]
Chlorinity using a titrator (potentiometric titration). milli-molar
osmo liquid chemistry::NO2 concentration: IC [mM]
Nitrite (NO2) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::Br concentration: IC [mM]
Bromine (Br) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::NO3 concentration: IC [mM]
Nitrate (NO3) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::SO4 concentration: IC [mM]
Sulfate (SO4) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::Na concentration: IC [mM]
Sodium (Na) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::K concentration: IC [mM]
Potassium (K) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::Mg concentration: IC [mM]
Magnesium (Mg) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::Ca concentration: IC [mM]
Calcium (Ca) concentration using an ion-exchange chromatograph. milli-molar
osmo liquid chemistry::B concentration: ICP-AES [µM]
Boron (B) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Ba concentration: ICP-AES [µM]
Barium (Ba) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Fe concentration: ICP-AES [µM]
Iron (Fe) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Li concentration: ICP-AES [µM]
Lithium (Li) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Mn concentration: ICP-AES [µM]
Manganese (Mn) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Si concentration: ICP-AES [µM]
Silicon (Si) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::Sr concentration: ICP-AES [µM]
Strontium (Sr) concentration using an inductively coupled plasma atomic emission spectrometer. micro-molar
osmo liquid chemistry::V concentration: ICP-MS [nM]
Vanadium (V) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Cu concentration: ICP-MS [nM]
Copper (Cu) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Rb concentration: ICP-MS [nM]
Rubidium (Rb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Mo concentration: ICP-MS [nM]
Molybdenum (Mo) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Cs concentration: ICP-MS [nM]
Cesium (Cs) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Pb concentration: ICP-MS [nM]
Lead (Pb) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::U concentration: ICP-MS [nM]
Uranium (U) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Y concentration: ICP-MS [nM]
Yttrium (Y) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Co concentration: ICP-MS [nM]
Cobalt (Co) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Cd concentration: ICP-MS [nM]
Cadmium (Cd) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::Cr concentration: ICP-MS [nM]
Chromium (Cr) concentration using an inductively coupled plasma mass spectrometer. nano-molar
osmo liquid chemistry::comment on measurement
Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.
osmo gas analysis
Measurements for gas samples from coiled tube collected by using Osmotic sampler.
osmo gas analysis::methane concentration: GC-FID [ppm]
Methane concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::ethylene concentration: GC-FID [ppm]
Ethylene concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::ethane concentration: GC-FID [ppm]
Ethane concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::propylene concentration: GC-FID [ppm]
Propylene concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::propane concentration: GC-FID [ppm]
Propane concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::i-butane concentration: GC-FID [ppm]
i-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::n-butane concentration: GC-FID [ppm]
n-butane concentration by using a gas chromatograph with a flame ionization detector. part per million
osmo gas analysis::comment on measurement
Comment on the measurement, the object (i.e. samples, for which the measurement is conducted) and/or errors that cannot be corrected.

The following(s) should be cited to refer this data set, with the exception of the post-expedition sampling records.

Saffer, D.Kopf, A.Toczko, S.the Expedition 365 Scientists2017NanTroSEIZE Stage 3: Shallow Megasplay Long-Term Borehole Monitoring SystemProceedings of the International Ocean Discovery Program365College Station, TX (International Ocean Discovery Program)http://dx.doi.org/10.14379/iodp.proc.365.2017

Processed at 2017-08-07T00:45:35Z. Center of Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology